Menu

Heatsink design

The Heatsink That Keeps the Junction Under 125 °C

Notes · Mechanical designNovember 19, 202622 min readSenova Systems Research

Thermal resistance is Ohm's law for heat: the junction temperature is the ambient plus the power times the resistance. A 100 W converter at 90% efficiency loses 11.1 W, a MOSFET's on-resistance doubles from 25 °C to 125 °C, and a heatsink inside a sealed box is cooling the part with hot air. The arithmetic for sizing the sink, and for knowing when no sink can do it.

Picture the board that works on the bench and dies in the field. On the bench, at 25 °C, the MOSFET is warm to the touch and the product passes every test. In the field, at 85 °C ambient, the same MOSFET throttles, the converter shuts down, and the product comes back, and the engineer who sized the heatsink cannot say why, because the heatsink is the same heatsink, and the MOSFET is the same MOSFET, and the only thing that changed is the air.

The answer is that the air is the design: the junction temperature is the ambient temperature plus the power times the thermal resistance, and when the ambient rises 60 °C, the junction rises 60 °C with it, and the part that had 40 °C of margin on the bench has none in the field.

A heatsink is not a cooler. It is a resistor, a thermal resistor, measured in degrees per watt, and sizing it is one line of arithmetic, done at the worst case, with the hottest numbers, against the air the sink actually sees. This article is that arithmetic: the one equation, the limit that is not a goal, the loss that is not the delivered power, the MOSFET whose resistance doubles as it heats, the TI worked example, the catalogue rating that only applies at the catalogue's airflow, the fins that have to stand vertically, the grease that has to be thin, the enclosure that is the heat path the sink feeds into, and the worst case that decides whether any sink can do it at all.

The words, in plain English

Junction (Tj). The silicon itself, inside the package, the hottest point in the part, and the temperature the datasheet limits. You cannot touch it and you cannot measure it directly; you calculate it.

Case (Tc). The outside of the package, the metal tab of a TO-220, the top of a chip. The temperature you can measure with a thermocouple, and the point the heat leaves the package through.

Ambient (Ta). The air around the part, and the number that decides everything, because it is the air the heatsink actually sees, which inside a sealed box is not the air outside it.

Thermal resistance (θ, theta). How many degrees the temperature rises for each watt of heat crossing a step, in °C/W. A thermal resistance of 5 °C/W means 5 W of heat raises the temperature 5 × 5 = 25 °C across that step. It is Ohm's law for heat: temperature is the voltage, power is the current, thermal resistance is the resistance.

Heatsink (θSA). The finned piece of aluminium bolted to the part. Its thermal resistance, sink to ambient, is the one number the heatsink exists to reduce, and the one number the catalogue quotes, at the catalogue's airflow, orientation, and profile length.

Derating. How much less power the part can dissipate as the ambient rises. The derating factor is the slope of that line, in mW/°C, and it is linear, so the part loses the same amount of capability for every degree the room gets hotter.

Junction-to-ambient (θJA). The total thermal resistance from the silicon to the air, with no heatsink: the package, the board, and the air, all in series. The datasheet number, and a board-dependent number, not a property of the chip alone.

The one equation

Heat flows from the junction, through the package, across the interface, into the heatsink, and from the fins into the air. Each step has its own thermal resistance, and they add in series, like resistors in an electrical circuit, which means the heatsink, no matter how well designed, can only be as effective as the weakest link in the whole chain.

Without a heatsink, the junction temperature is:

Tj = Ta + P × θJA

With a heatsink, the heat takes a different path, and the total is the sum of the three steps:

Tj = Ta + P × (θJC + θCS + θSA)

where θJC is junction to case (set by the package, 5.0 °C/W for the MC7805 and the LM317 in TO-220, 0.5–5 °C/W for TO-220 and TO-247 generally), θCS is case to sink (the interface, typically 0.2–1 °C/W, 0.3–0.6 °C/W with grease), and θSA is sink to ambient (the heatsink, 5–15 °C/W in natural convection, 1–5 °C/W in forced air at 100–400 LFM, from 30 °C/W for a small clip to below 1 °C/W for a large sink or a fan). Turn the equation round and the heatsink you need is:

θSA,max=(Tj,target−Ta)/P−θJC−θCS\text{θSA,max} = \text{(Tj,target} - \text{Ta)} / \text{P} - \text{θJC} - \text{θCS}

If the answer is zero or negative, no heatsink can do it, and the design needs a lower loss, not a bigger sink. That is the first thing the arithmetic tells you, and it is the thing most designs never check: a heatsink cannot make heat disappear. It can only move it into the air, and if the air is already hotter than the junction is allowed to be, there is no heatsink in the catalogue that helps.

Several devices on one heatsink share it: the heatsink carries the total power, and each device adds its own rise on top, Ts = Ta + N × P × θSA, and Tj = Ts + P × (θJC + θCS). The sink sees the sum; each device sees its own junction-to-case on top of the sink temperature. A sink that is fine for one MOSFET can be too small for two.

Tjmax is a limit, not a design goal

The maximum allowable junction temperature is usually 150 °C, or 125 °C on many parts, and it is a limit, not a design goal. The onsemi MC7805 has an operating junction temperature of 150 °C, but its electrical characteristics are specified for Tj up to 125 °C, and the guides that work the arithmetic use 125 °C as the design limit. The rule, from the calculator guides, is to stay 20–30 °C below the absolute maximum for reliability.

Hitop's version is the same: design for Tj = 125 °C rather than the absolute maximum of 150–175 °C, for reliability margin.

The reason is the derating curve: as the ambient approaches the maximum allowed junction temperature, the part must be derated, and the allowable dissipation shrinks linearly. The TI worked example makes the slope visible. The TPS54325, in TI's SLVA462 application report, has θJA of 44.5 °C/W and Tjmax of 125 °C, which gives a maximum dissipation of 2.25 W at 25 °C ambient and 0.9 W at 85 °C ambient.

The derating factor is 2,250 mW for a 100 °C rise, which is 22.5 mW/°C, for each one degree the ambient rises, the power dissipation rating has to fall 22.5 mW. The same part loses 60% of its dissipation capability between a 25 °C bench and an 85 °C field, and the loss is linear: 1.80 W at 45 °C, 1.35 W at 65 °C, 0.90 W at 85 °C, 0.45 W at 105 °C.

A design that dissipates 2 W at 25 °C and passes has no margin at 45 °C and fails at 65 °C, and the failure is not a surprise. It is the derating curve, read as a line.

The heat to remove is the loss, not the delivered power

The first mistake in heatsink design is sizing for the delivered power. The heat to remove is the loss, the power the circuit turns into heat, not the power it delivers to the load. A 100 W converter at 90% efficiency loses ~11.1 W: it takes 111.1 W in and delivers 100 W out, and the 11.1 W difference is heat, sitting in the switches, the inductor, and the diodes.

The heatsink has to remove 11.1 W, not 100 W, and the design that sizes for 100 W buys a sink ten times too big, while the design that sizes for the efficiency at the wrong load point buys one too small, because efficiency is worst at the load the product actually runs at.

The linear regulator is the extreme version. A 7805 dropping 12 V to 5 V at 1 A turns 7 W into heat to deliver 5 W to the load, and the bare package, with θJA of 65 °C/W, can handle only 1.54 W at 125 °C in 25 °C air. The heatsink it needs is θSA = (125 − 25) / 7 − 6 = 8.2 °C/W or better (Science360, using θJC + θCS = 6 °C/W).

The ElectronicsInfoline worked example is the same lesson at a smaller scale: 5 V out at 500 mA from 12 V, 3.50 W of drop plus 60 mW of quiescent current, 3.56 W total, against 2.50 W delivered, 41.3% efficiency, more heat leaving the regulator than power reaching the load. The path is 3.0 °C/W junction to case, 0.80 °C/W case to sink, and 6.5 °C/W sink to air, 10.3 °C/W in all, and at 3.56 W that costs 10.7 °C, 2.85 °C, and 23.1 °C, a rise of 36.7 °C, of which the sink is 63.1%.

From a 30 °C room the junction reaches 66.7 °C, leaving 73.3 °C below the 140 °C limit. Bare, the ceiling is 1.77 W; with the sink it is 10.7 W, 6.02 times more dissipation from the same die, and the regulator needs 3.56 W, which only the second arrangement allows. Bare, at 3.56 W, the junction would reach 250.7 °C.

That is not a design that runs hot. It is a design that has already failed.

The MOSFET's loss grows as it heats

The second mistake is sizing with the 25 °C resistance. A MOSFET's on-resistance has a strong positive temperature coefficient: as the silicon gets hotter, the carrier mobility falls, the channel resistance rises, and the conduction loss, I² × Rds(on), rises with it. EDN's tutorial puts the number plainly: on-resistance approximately doubles from 25 °C to 125 °C, and the strong positive temperature coefficient compounds the I²R conduction loss as temperature increases.

Hackaday's version: for every 10 °C increase in temperature, Rds(on) may increase by 5–10%, and in a hot enclosure it can double. Adeoworks' version: at 100 °C, Rds(on) can double; at 125 °C, it can be 2.5 times higher, a 40 V MOSFET with a stated Rds(on) of 10 mΩ at 25 °C is more like 25 mΩ at 120 °C, and at 20 A that is 10 W of dissipation, not 4 W.

The feedback loop is the danger, and the #23 piece named it as one of the five ways a motor driver dies: heat that feeds on itself as the on-resistance climbs. The silicon gets hotter, the resistance rises, the loss rises, the silicon gets hotter, and if the rate of heat generation exceeds the rate of heat removal, the temperature climbs without bound. The datasheet Rds(on) is specified at 25 °C junction temperature, and that is a cruel joke for a part that will run at 125 °C: if the conduction loss was calculated with the 25 °C number, it is under-estimated by a factor of two in a hot enclosure.

Always use the maximum Rds(on) at the highest expected junction temperature for the current calculations, and the design power is the hot figure, not the cold one. The positive coefficient is a nice feature when paralleling MOSFETs, because it ensures thermal stability, but it does not ensure even current sharing, and it does not save a design that sized the sink for the cold resistance.

The TI worked example, in full

TI's SLVA462 application report works the whole calculation on a real part, and it is worth following because it shows where each number comes from. The TPS54325 is a 4.5 V to 18 V, 3 A synchronous buck converter, in a 14-pin HTSSOP package, designed to operate from −40 °C to 85 °C, with integrated FETs of 120 mΩ (high side) and 70 mΩ (low side). The application report's example is a 5 V input, 2.5 V output, 1 A load, 2.5 W delivered to the load.

The total loss is 250 mW, and the inductor takes its share first: Pinductor = Iout² × DCR = 1² × 100 mΩ = 100 mW. The device dissipation is then 250 mW − 100 mW = 150 mW, and the junction temperature rise above ambient is θJA × PD = 75 °C/W × 0.15 W = 11.25 °C above ambient (the report uses 75 °C/W as the example thermal resistance for this step).

The inductor is not a detail: it is 40% of the loss, and the device is 60%, and a design that attributes all 250 mW to the converter over-sizes the converter's sink and under-sizes nothing, because the inductor's 100 mW still has to go somewhere, and it goes into the same board, in the same box, heating the same air.

Read the catalogue °C/W at your real airflow, orientation, and profile length

The catalogue thermal resistance is a rating at stated conditions, and the conditions are the design. Natural-convection and forced-air ratings are not interchangeable: a sink rated 5 °C/W at 200 LFM of forced air is not a 5 °C/W sink in still air, and a sink rated in free air is not a 5 °C/W sink inside a sealed box. The typical ranges, 5–15 °C/W in natural convection, 1–5 °C/W in forced air at 100–400 LFM, from 30 °C/W for a small clip to below 1 °C/W for a large sink or a fan, are the right order of magnitude, and the catalogue value is the one to use, at the airflow the product actually has.

If the product has no fan, the natural-convection rating is the one that applies, and the forced-air rating is a number for a different product.

The fin geometry is the same story: more surface area means more heat rejected for a given temperature difference, but packing the fins closer together runs into diminishing returns fast, and past a certain point it actively hurts, the boundary layer of slow-moving air along each fin surface overlaps with the boundary layer from the neighbouring fin, choking off airflow through the channel and increasing the pressure drop. Doubling the fin count can barely improve thermal performance at all, because the airflow through the tighter channels drops enough to offset almost all of the added surface.

For natural convection, fin gaps of around 6 mm or more are a reasonable starting point, and taller fins need wider spacing to maintain airflow. With forced airflow, denser fins can work, but the channels have to align with the airflow direction, and the pressure drop has to be watched.

Mount the fins vertically, and do not block the air

For natural convection, mount the fins in the vertical plane for optimum cooling, the channels run vertically, cooler air enters from below, and warm air rises through the channels in the chimney effect. With horizontal channels, the rising air is blocked, which reduces cooling. Do not block airflow around the heatsinks, particularly directly above and below items that rely on natural convection, and do not overcrowd or obstruct devices that use heatsinks.

In an enclosed case, trapped warm air hurts performance more than fin orientation, and vents at the bottom and the top help, because they let the chimney work.

The interface is the step most designs add as an afterthought, and it is the step that most often decides the result. Two machined metal surfaces never touch perfectly, microscopic air gaps act as insulation, and a thermal interface material fills those gaps. Always use some form of heatsink grease or a thermally conductive pad between the heatsink and the device; excessive quantities of grease will decrease performance.

Grease gives the lowest thermal resistance but must be applied thinly and evenly, and it can dry or pump out over time; a pad is easier to assemble and isolates electrically, at slightly higher thermal resistance; a mica sheet isolates electrically but is brittle and needs grease on both faces. Mounting torque matters: too little torque leaves air gaps, while too much can crack the body or crush the pad.

The grease adds about 0.8 °C/W (LibreTexts), and in one field case, a thermal pad substituted for the originally specified grease during a cost-reduction pass contributed nearly 40% of the total junction-to-ambient resistance, and reverting to a properly applied thermal grease with a thinner, more consistent bond line dropped the junction temperature by over 15 °C without changing a single dimension on the heatsink. The interface is not a detail.

It is a resistor in the chain, and it has to be budgeted like one.

The enclosure is the heat path the sink feeds into

The heatsink's ambient is not the room. It is the air inside the enclosure, and the #7 piece measured that air: a sealed 100 × 60 × 40 mm box with 5 W inside runs 25 °C hotter than the air around it. That is 5 °C/W for the enclosure, and it is the resistance the heatsink feeds into: the sink moves heat from the part into the inside air, and the enclosure moves it from the inside air to the outside air, and the two resistances add.

A heatsink inside a sealed box is cooling the part with hot air, and the hotter the box gets, the less the sink can do.

The board copper is part of the same chain, and it is the part the heatsink cannot replace. The TPS54325's current datasheet lists RθJC(bot) of 4.3 °C/W, the path from the junction down through the exposed pad into the board, against RθJC(top) of 51.3 °C/W. The heat leaves through the bottom, into the copper, and the copper has to be there: the thermal pad, the vias, and the ground plane are the heatsink for a surface-mount part, and a part with no copper under it has no path out.

The #5 piece's DFM rules and the #32 piece's test points are the same board, and the thermal path is laid out on it at the same time as the electrical one.

Use the worst-case maximum dissipated power

The calculation is done at the worst case: maximum input voltage, maximum load current, and maximum ambient temperature, including internal enclosure heating, and with the hottest Rds(on), not the 25 °C one. The rule comes from the LDO thermal design guides and the calculator guides, which state it in the same terms: use the worst case, highest input voltage, largest current, hottest Rds(on).

The load and the line voltage both vary, and the loss varies with them: a converter at the top of its input range and the top of its load range dissipates more than the same converter at the nominal point, and the design that sizes for the nominal point fails at the corner. The calculation is for steady state, constant power, and short pulses heat the junction less, because the package's thermal capacity absorbs them; for those, use the datasheet's transient thermal impedance, not the steady-state θJA.

Example Labs is a made-up company we use for worked examples.

DEMO

The Example Labs field sensor hub is the demo firm: a 100 × 60 × 40 mm unit, 4-layer board, BLE radio at 2.4 GHz, plastic enclosure from #7. The charger is the 48 V bench pack from #20/#23, 13S1P NMC, 3.5 Ah/cell, 48.1 V nominal, 54.6 V full, 39.0 V empty, 168 Wh, and the converter charges it from the USB-C PD port from #33, at 48 V and 5 A. The arithmetic was run in Python before writing.

Step 1, the loss, not the delivered power. The converter delivers 100 W to the pack at 90% efficiency. It takes 111.1 W in and delivers 100 W out, so the loss is 11.1 W, and that is the heat to remove, not the 100 W. The 11.1 W sits in the switches, the inductor, and the diodes, in the same box, heating the same air.

Step 2, the MOSFET, hot and cold. One MOSFET carries 20 A, with Rds(on) of 10 mΩ at 25 °C. The conduction loss at 25 °C is 20² × 0.010 = 4.0 W. At 125 °C the resistance approximately doubles to ~20 mΩ (EDN), and the loss is 20² × 0.020 = 8.0 W. The design power is 8.0 W, the hot figure, not the cold one. A design that sized the sink for 4.0 W under-sized it by a factor of two.

Step 3, the TI example, on the same numbers. The TPS54325, θJA 44.5 °C/W, Tjmax 125 °C: maximum dissipation 2.25 W at 25 °C ambient and 0.90 W at 85 °C ambient, derating 22.5 mW/°C. The same part loses 60% of its dissipation capability between the bench and the field, and the loss is linear, 1.80 W at 45 °C, 1.35 W at 65 °C, 0.90 W at 85 °C, 0.45 W at 105 °C.

Step 4, the heatsink the MOSFET needs. TO-220: θJC 5.0 °C/W, θCS 0.5 °C/W with grease, P = 8.0 W, Tj target 125 °C. At 25 °C ambient, θSA ≤ (125 − 25) / 8 − 5.0 − 0.5 = 7.0 °C/W. At 40 °C ambient, θSA ≤ 5.1 °C/W. At 85 °C ambient, θSA ≤ −0.5 °C/W, negative, so no heatsink can do it, and the design needs a lower loss: a better MOSFET, a lower current, or a different topology. A 6.5 °C/W sink at 25 °C ambient gives Tj = 25 + 8 × (5.0 + 0.5 + 6.5) = 121 °C, it passes on the bench. The bench passes and the field fails, and the reason is the ambient.

The same sink at 85 °C ambient gives Tj=85+96=181 °C, it fails in the field\text{The same sink at 85 °C ambient gives Tj} = 85 + 96 = \text{181 °C, it fails in the field}

Step 5, the enclosure, and the air the sink actually sees. The sealed box from #7: 5 W inside raises the inside air 25 °C, which is 5 °C/W for the enclosure. The converter's 11.1 W loss inside the same box adds +55.6 °C to the inside air. At 85 °C outside, the inside air is 140.6 °C, above the 125 °C junction target before the MOSFET dissipates anything. The heatsink cannot fix it, because the heatsink's ambient is the inside air, and the inside air is already hotter than the junction is allowed to be. The fix is not a bigger sink: it is to vent the box, move the converter out of the sealed enclosure, or cut the loss, and the 11.1 W is the total, of which the MOSFET's 8.0 W is the largest single contributor.

Step 6, the interface eats the budget. With θCS of 0.5 °C/W (grease, thin and even), the MOSFET needs θSA ≤ 7.0 °C/W at 25 °C. With θCS of 1.0 °C/W (a pad, or too much grease), it needs θSA ≤ 6.5 °C/W, the interface has eaten 0.5 °C/W of the budget, which is the difference between a sink that fits and a sink that does not. The LibreTexts figure is ~0.8 °C/W for the grease alone, and the Sekkei-Tech field case cost 15 °C for a substituted pad.

Step 7, the three options for the hub. (a) A better MOSFET, a lower Rds(on) at 25 °C, so the hot loss falls from 8.0 W toward 4.0 W, and the sink the design needs moves from 7.0 °C/W to 19.5 °C/W at 25 °C ambient. (b) A bigger sink, fins vertical, the airflow unblocked above and below, in a box with vents at the bottom and the top. (c) Vent the enclosure or move the converter out of the sealed box. The recommendation is (a) and (c) first, cut the loss and give the heat somewhere to go, and the sink is the last resort, not the first, because a sink inside a sealed box is cooling the part with hot air.

The decision test: five questions

A power lead whose board runs hot can answer five questions in an afternoon. If the answer to three of them is no, the heatsink is not the fix, or the design is not ready for one.

  1. What is the loss, at the worst case? If the design power is the delivered power, or the nominal efficiency, or the 25 °C Rds(on), the arithmetic is wrong before it starts. The loss is the worst-case maximum: highest input voltage, largest current, hottest Rds(on), and the efficiency at the load the product actually runs at.
  2. What is the ambient the sink actually sees? If the answer is the room temperature, it is wrong: inside a sealed box, the ambient is the room plus the enclosure's rise, 5 W inside the Example Labs box is +25 °C, and 11.1 W is +55.6 °C. If the inside air is already above the junction target, no sink can do it.
  3. What is the heatsink you need, and does it exist? If θSA,max is zero or negative, the design needs a lower loss, not a bigger sink. If it is positive, the catalogue value has to be read at the product's real airflow, orientation, and profile length, not at the catalogue's.
  4. What is the interface, and is it budgeted? If the grease is an afterthought, the interface is a resistor the design has not counted, and it can be 40% of the total. The interface material, the screw torque, and the board copper all move the result, and they have to be budgeted, not added after the fact.
  5. What is the derating, and where does the design sit on it? If the junction is at 125 °C at the worst case, the design has no margin: the derating curve says the part loses 22.5 mW/°C of capability, and the next degree of ambient takes it over the limit. The target is 20–30 °C below the absolute maximum, not at it.

Objections

"We'll just use a bigger heatsink." A bigger sink lowers θSA, and θSA is only one of three resistances in the chain. If θJC is 5 °C/W and the interface is 1 °C/W, the chain is 6 °C/W before the sink, and at 8 W, that is 48 °C of rise with no sink at all. A bigger sink helps when θSA is the binding term; it does nothing when the interface or the enclosure is. And if θSA,max is negative, there is no sink in the catalogue that helps.

"The part is rated to 150 °C, so 140 °C is fine." The rating is a limit, not a design goal, and the electrical characteristics are specified to 125 °C. The part at 140 °C is a part whose characteristics are no longer guaranteed, whose Rds(on) has doubled, whose leakage current has doubled roughly every 10 °C, and whose lifetime is shorter than the part at 125 °C by a factor the derating curve does not state but the reliability guides do. Design for 125 °C. Stay 20–30 °C below the absolute maximum.

"We'll add a fan." A fan is forced convection, and it changes the rating, 1–5 °C/W instead of 5–15 °C/W, but it also adds noise, power, and dust, and it pulls contamination into the fins, degrading performance over time. A fan is a legitimate fix, and it is also a moving part in a product that has to run for years in the field. If the design needs a fan to pass, the design should say so, and the fan should be in the bill of materials, the power budget, and the reliability analysis, not added after the fact.

"The bench test passed, so the design is fine." The bench is 25 °C, and the field is 85 °C, and the part loses 22.5 mW/°C of capability between them. The 6.5 °C/W sink that gives Tj = 121 °C on the bench gives 181 °C in the field. The bench test is a test at the wrong ambient, and the design that passes it has not been tested at all.

"We'll just use thermal paste and be done with it." Thermal paste is the interface, and the interface is a resistor. Too much grease hurts, a pad is slightly higher resistance than grease, and the mounting torque matters. The interface can be 40% of the total junction-to-ambient resistance, and in one field case a substituted pad cost 15 °C. Paste is not a substitute for arithmetic.

Sources

  1. TI, "Understanding Thermal Dissipation and Design of a Heatsink" (SLVA462, May 2011)
    What we used

    TJ = TA + P × θJA; θJA 44.5 °C/W and Tjmax 125 °C for the TPS54325; maximum dissipation 2.25 W at 25 °C ambient, 0.9 W at 85 °C ambient; derating factor 22.5 mW/°C (2,250 mW for a 100 °C rise); the worked example (5 V in, 2.5 V out at 1 A, 2.5 W delivered; total loss 250 mW; inductor P = Iout² × DCR = 100 mW; device dissipation 150 mW; junction rise 75 °C/W × 0.15 W = 11.25 °C above ambient); θJA is made up of at least two separate thermal resistances in series

  2. TI, TPS54325 datasheet (SLVS932F, Rev F, November 2014)
    What we used

    RθJA 55.6 °C/W, RθJC(top) 51.3 °C/W, RθJB 26.4 °C/W, RθJC(bot) 4.3 °C/W, ΨJT 1.8 °C/W, ΨJB 20.6 °C/W; thermal shutdown threshold 150 °C, hysteresis 25 °C; 4.5–18 V input, 3 A output, 14-pin HTSSOP, −40 °C to 85 °C operating; integrated FETs 120 mΩ (high side) and 70 mΩ (low side)

  3. The Science 360, "Does My 7805 Need a Heatsink?"
    What we used

    Onsemi MC7805C θJA 65 °C/W (TO-220), operating junction 150 °C but characteristics specified to 125 °C; Pmax at 125 °C in 25 °C air = 1.54 W; heatsink needs θSA = (125 − TA) / P − 6 °C/W; from 12 V at 1 A, 8.2 °C/W or better; θJC 5.0 °C/W for the MC7805 and LM317 in TO-220

  4. Hitop, "Power Transistor Thermal Design: SOA, Heat Sink & Derating"
    What we used

    TJ = TA + (PD × θJA); θJA = θJC + θCS + θSA; θJC typically 0.3–5 °C/W, θCS 0.2–1 °C/W, θSA 1–20 °C/W; θSA (natural convection) 5–15 °C/W, θSA (forced air) 1–5 °C/W at 100–400 LFM; θCS with grease 0.3–0.6 °C/W; θSA(required) = [(TJ(max) − TA(max)) / PD(max)] − θJC − θCS; design for TJ = 125 °C rather than the absolute maximum (150–175 °C) for reliability margin; conduction loss PD = ID² × Rds(on) × (1 + α × [TJ − 25 °C]); switching loss PD = (VDS × ID × [tr + tf] × fsw) / 2

  5. Toolformula, "Heatsink & Junction Temperature Calculator"
    What we used

    TJ = TA + P × (θJC + θCS + θSA); θSA ≤ (TJ,target − TA) / P − θJC − θCS; a result at or below zero means no heatsink can do it; several devices on one heatsink: TS = TA + N × P × θSA, TJ = TS + P × (θJC + θCS); use the worst case: highest input voltage, largest current, hottest Rds(on); stay 20–30 °C below the absolute maximum for reliability; θSA from 30 °C/W (small clip) to below 1 °C/W (large or fan); the worked example (12 V to 5 V at 0.5 A, 3.5 W; bare limit 1.37 W; required heatsink 20.8 °C/W; with a 19 °C/W sink, TJ = 119 °C)

  6. Engineering LibreTexts, "8.6: Heat Sinks"
    What we used

    Always use heatsink grease or a thermally conductive pad; excessive quantities of grease decrease performance; mount fins in the vertical plane for optimum natural convective cooling; do not overcrowd or obstruct devices that use heatsinks; do not block airflow around heatsinks, particularly directly above and below items that rely on natural convection; the grease adds ~0.8 °C/W

  7. SierraConnect, "Heatsink fin orientation for natural convection"
    What we used

    For natural convection on a vertical PCB, orient the fins so the channels run vertically (chimney effect: cooler air enters from below, warm air rises through the channels); horizontal channels block the rising air; fin gaps of around 6 mm or more for natural convection; in an enclosed case, trapped warm air hurts more than fin orientation, and vents at the bottom and top help; Rds(on) rises significantly with junction temperature, so losses at operating temperature are higher than at 25 °C

  8. Sekkei-Tech, "Heat Sink Design Basics"
    What we used

    Map the entire thermal resistance path from junction to ambient; the mounting interface can contribute nearly 40% of the total junction-to-ambient resistance; in one field case, reverting from a substituted thermal pad to a properly applied thermal grease with a thinner, more consistent bond line dropped the junction temperature by over 15 °C without changing a heatsink dimension; doubling the fin count can barely improve performance because the airflow through the tighter channels drops enough to offset the added surface

  9. Dev.to, "Heat Sinks and Thermal Management for Power Resistors"
    What we used

    Every 10 °C of temperature rise roughly halves the expected life of the insulation; mounting torque matters (too little leaves air gaps, too much can crack the body or crush the pad); grease gives the lowest thermal resistance but must be applied thinly and evenly; a pad is slightly higher resistance; keep the thermal interface thin and even

  10. EDN, "Power MOSFET tutorial, Part 1"
    What we used

    On-resistance approximately doubles from 25 °C to 125 °C; the strong positive Rds(on) temperature coefficient compounds the I²R conduction loss as temperature increases; the positive coefficient ensures thermal stability when paralleling MOSFETs but does not ensure even current sharing

  11. Hackaday.io, "Reasons for Increased Internal Resistance in MOSFETs After Use"
    What we used

    For every 10 °C increase in temperature, Rds(on) may increase by 5–10%; in high-temperature environments, internal resistance can double

  12. Adeoworks, "Troubleshooting MOSFET Overheating and Thermal Runaway"
    What we used

    At 100 °C, Rds(on) can double; at 125 °C, it can be 2.5 times higher; a 40 V MOSFET with 10 mΩ at 25 °C is more like 25 mΩ at 120 °C, and at 20 A that is 10 W of dissipation, not 4 W; always use the maximum Rds(on) at the highest expected Tj for current calculations

  13. ElectronicsInfoline, "Linear Regulator Thermal Design"
    What we used

    The worked example (5 V out at 500 mA from 12 V, 3.56 W total, 41.3% efficiency; path 3.0 + 0.8 + 6.5 = 10.3 °C/W; rise 36.7 °C; junction 66.7 °C from a 30 °C room; bare ceiling 1.77 W, with the sink 10.7 W, 6.02× more dissipation from the same die; bare at 3.56 W, the junction would reach 250.7 °C)

  14. Dev.to, "Thermal Design and Junction Temperature in LDOs"
    What we used

    The designer should always perform this calculation at worst case: maximum input voltage, maximum load current, and maximum ambient temperature, including internal enclosure heating; as the ambient approaches the maximum allowed junction temperature, the part must be derated

  15. Microchip, MicroNote 070, "Thermal Management for Discrete Semiconductors"
    What we used

    TJ = P × RθJA + TA; RθJA is the thermal resistance from the junction to a natural convection environment; the acceleration factor from temperature changes follows the Arrhenius form (JEDEC JEP122H)

  16. Example Labs figures from the cluster: the 48 V bench pack (13S1P NMC, 3.5 Ah/cell, 48.1 V nominal, 54.6 V full, 39.0 V empty, 168 Wh
    What we used

    #20/#23); the 100 W converter at 90% efficiency loses 11.1 W (#6/#33); the sealed 100 × 60 × 40 mm box with 5 W inside runs 25 °C hotter than the air around it (#7); the MOSFET failure mode of heat feeding on itself as the on-resistance climbs (#23)

More in design notes

The Screw That Doesn't StripThe housing has to open for battery service and calibration, and every time it opens, the joint gets weaker. A self-tapping screw holds 380 N on the first pass and is stripped by the eleventh; a brass insert still holds 1,056 N at pass 25. The strength does not come from the brass, it comes from plastic locked into the knurls.21 minThe Seal That Actually SealsYour enclosure passed IP65 on the bench and leaks in the field, because the gasket took a set after two years of temperature cycling and the joint designed at 30% compression is now working at 15%. The seal is a set of numbers, not a material.26 minTolerance Stack-UpEvery part is a little off, and the little offs add up. Ten parts at ±0.1 mm stack to ±1.00 mm worst case and ±0.32 mm statistically, and the difference between those two answers is the difference between a product that assembles and a product that doesn't. The fix is rarely a tighter tolerance. It is usually a shorter chain.14 minPower Design for Battery ProductsThe battery is a budget, not a box. A field sensor on a CR2032: the headline budget says 513 days, the measured budget says 44. The gap is sleep current, regulator losses, and a battery that is not a constant, and the fix is arithmetic, not a bigger cell. The power budget, the BMS, and the rules that make battery life honest.14 minThe Battery's BrainA battery management system is three things at once: the eyes that measure every cell, the accountant that estimates how much charge is left, and the guard that disconnects the pack before a fault becomes a fire. This is how to design each one, the measurement accuracy that decides how much capacity you waste, the SOC estimation that has no sensor to read, the balancing choice, and the protection thresholds with real margin, with a worked demo on a 48 V pack.28 min