Precision measurement

Getting a number you can trust: calibration, accuracy, current sensing, noise and integrity.

Notes 6

The Ground That Isn't a GroundOn the schematic every ground symbol is the same point. On the board they are joined by copper, and copper has resistance and inductance, so the ground at the sensor is not the ground at the ADC. The fix is a plane, a return under the trace, and one bridge between the noisy and the quiet.24 minEMC pre-compliance testingAbout half of products fail EMC testing on the first attempt, and each failure costs $5,000–$30,000 and 2–6 weeks. A pre-compliance scan on your own bench finds the failure before the lab does, for $300–$800 a scan.30 minThe Rail That Doesn't RingYour schematic is correct and your board still fails EMC. The problem is in the layout: the hot loop, the switch node, and the ground that is not one ground. Here is the buck converter's noise, measured in numbers.20 minThe Rail That SagsThe processor wakes up, the rail droops, the board resets, the clock jitters, the radio loses packets, and the schematic is correct, because the problem is the impedance of the power delivery network, not the regulator.22 minSensor Calibration and DriftA gyroscope measures rate, not angle, the angle is the integral of the rate, so any bias is integrated too: a bias of 0.1°/s adds 6° of error every minute, 360° in an hour. Bias is the offset the sensor reads at rest; it shifts with temperature and time, and random noise adds its own slow wander (a random walk whose standard deviation grows with the square root of time). The fixes are simple and in order: measure the bias at startup while the device is still and subtract it; recalibrate continuously when the device rests; fuse with an accelerometer (complementary filter, α ≈ 0.98), the accelerometer gives tilt with no drift when still, the gyro gives smooth fast motion. Yaw has no gravity reference, so it needs a magnetometer. Even a well-calibrated gyroscope cannot be trusted for hours without a second sensor to check against.24 minThe Spec Sheet That Lies About AccuracyA sensor can be precise without being accurate, a tight cluster of readings, far from the true value. Accuracy is closeness to the true value; precision is how tightly repeated readings group; resolution is the smallest detectable change. The Levelogger 6 M100's resolution is 0.6 mm on a 100 m full scale, 83 times finer than its ±5 cm accuracy. Averaging fixes random noise; it cannot fix systematic error. That needs calibration against a known reference.22 min